CF1200 -2 loop Panel

CF1100 - CF1000 - Addressable fire alarm system panel

The Eaton CF1200 is a two-loop, intelligent, addressable fire control panel suitable for small to medium-sized projects. Like the one-loop CF1100, the CF1200 boasts sophisticated functionality and simple end-user operation.
Here are some key features of the CF1200:
Two-Loop Control: The CF1200 manages up to 200 addresses per loop—a total of 400 addresses—making it suitable for larger businesses or those with more complex fire safety needs.
User-Friendly Interface: The CF1200, like the CF1100, features a large, versatile touchscreen for simple system monitoring and operation .
Advanced Networking: The CF1200 can connect with up to 126 other Eaton CF1000 and CF3000 panels using an optional network card for expanded coverage and centralized control.
Reliable Performance: The CF1200 includes an integrated power supply and comes standard with batteries to ensure continuous operation even during power outages.
Flexible and Scalable: The CF1200 is compatible with various intelligent, addressable ancillary devices from Eaton, including repeater panels such as the CF3000PRG and CTPR3000. This compatibility allows businesses to build a comprehensive and customized fire safety system.
The CF1200 shares the following features with the CF1100:
Soft addressing minimizes installation time and the potential for error
Two conventional sounder circuits (monitored for open and short circuits) with a maximum combined output of 1.5A
A 24V DC, 30mA (max) auxiliary fire routing equipment output (monitored)
A 24V DC, 30mA (max) auxiliary fire protection equipment output (monitored)
A 12V DC, 30mA (max) auxiliary fault routing equipment output (monitored)
A 24V DC (nominal) system operating voltage
A 230V AC, +10/-15% main input supply
Class change facility terminals
One set of changeover contacts that operate in the event of a fire condition
RS485 and RS232 output ports for connecting repeaters and other devices
A standby duration dependent on loop loading and battery configuration
Two 12V, 7Ah batteries
An operating temperature of -5°C to +40°C
A humidity (non-condensing) tolerance of 0% to 93% (+2/-3% RH)
Steel back box construction
Dimensions of 375mm x 357mm x 95 mm (H x W x D)
A weight of 8 kg
IP30 ingress protection
Top cable knockouts (20mm) and rear cable aperture cable entries
Compliance with the following standards: EN54 Pt2,1997, A1:2006, EN54 Pt4,1997 A1:2002, A2:2006, EN54 Pt13: 2005
The Eaton CF1200’s combination of features, including its dual-loop design, networking capabilities, and user-friendliness, make it a compelling fire safety solution for a range of businesses and applications.